Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 151
Filter
1.
Odovtos (En línea) ; 25(2)ago. 2023.
Article in English | LILACS-Express | LILACS | ID: biblio-1448738

ABSTRACT

The aim of this study was to evaluate the whitening and abrasion effects of dentifrices containing different whitening agents on artificially stained and unstained enamel. 160 human dental enamel discs were distributed into four groups according to the type of dentifrices applied on them (n=40): Group I, non-whitening dentifrice (control group); Group II, dentifrice containing charcoal; Group III, dentifrice containing blue covarine; Group IV, dentifrice containing hydrogen peroxide. Half of the specimens in each group were immersed in coffee solution. Color measurements were evaluated from stained and unstained specimens before and after brushing by a spectrophotometer. The surface roughness of each unstained specimen was analyzed using a profilometer after the brushing and bleaching. The surface of one randomly selected specimen from each group was observed using a scanning electron microscope (SEM). Statistical analysis of the color change was performed using the Kruskal-Wallis test. The one-way ANOVA was used to evaluate surface roughness. Group III provided significantly higher recovery on ΔE00 values than other groups on the unstained enamel (p<0.05). Group IV showed significantly the highest ΔE00 values on stained enamel (p<0.05) and also Group IV showed the highest surface roughness values (p<0.05), SEM revealed a more irregular surface in groups III and IV. It can be stated that dentifrice containing blue covarine is both an effective and a safe way to provide whiter teeth with routine home tooth brushing.


El objetivo de este estudio fue evaluar los efectos de blanqueamiento y abrasión de los dentífricos que contienen diferentes agentes blanqueadores en el esmalte teñido y no teñido artificialmente. Se distribuyeron 160 discos de esmalte dental humano en cuatro grupos según el tipo de dentífrico aplicado sobre ellos (n=40): Grupo I, dentífrico no blanqueador (grupo control); Grupo II, dentífrico que contiene carbón vegetal; Grupo III, dentífrico que contiene azul; Grupo IV, dentífrico que contiene peróxido de hidrógeno. La mitad de los especímenes de cada grupo se sumergieron en una solución de café. Las mediciones de color se evaluaron a partir de especímenes teñidos y no teñidos antes y después del cepillado con un espectrofotómetro. La rugosidad de la superficie de cada muestra sin teñir se analizó utilizando un perfilómetro después del cepillado y del clareamiento. La superficie de un espécimen seleccionado al azar de cada grupo se observó utilizando un microscopio electrónico de barrido (MEB). El análisis estadístico del cambio de color se realizó utilizando la prueba de Kruskal-Wallis. Se utilizó el ANOVA para evaluar la rugosidad de la superficie. El grupo III proporcionó una recuperación significativamente mayor en los valores de ΔE00 que otros grupos en el esmalte no teñido (p<0,05). El Grupo IV mostró significativamente los valores más altos de ΔE00 en el esmalte teñido (p<0.05) y también el Grupo IV mostró los valores más altos de rugosidad superficial (p<0.05), el análisis en MEB reveló una superficie más irregular en los grupos III y IV. Se puede afirmar que el dentífrico que contiene azul es una forma efectiva y segura de proporcionar dientes más claros con el cepillado de rutina en el hogar.

2.
STOMATOLOGY ; (12): 46-51, 2023.
Article in Chinese | WPRIM | ID: wpr-965135

ABSTRACT

Objective @#To observe the clearance of smear layer on the root canal wall in different action time by scanning electron microscope (SEM), and to determine the optimal amount of time using sonically activated irrigation to wash root canal in clinic. @*Methods@# Fifty-six ex vivo human anterior teeth with single straight root canal were selected. After routine mechanical preparation, they were divided into two experimental groups according to different irrigating agents: saline group and EDTA group. Each group was assisted by VDW sonic activation EDDY. The saline group was divided into three subgroups according to the irrigating time: 5 s, 30 s and 50 s; EDTA group was divided into six subgroups according to the irrigating time: 5 s, 10 s, 20 s, 30 s, 40 s and 50 s. The control group did not undergo root canal irrigation. After irrigation, the root was cut longitudinally. The smear layer of crown, middle and apical of root canal wall was observed by SEM.@* Results@# After irrigating for 30 seconds, there was a significant difference between the normal saline group and the control group and the 5 second group (P<0.05), and there was no difference in the middle and apical part (P>0.05). After 50 seconds, there was a significant difference in the score of the smear layer between the apical area and the other groups (P<0.05). After irrigating for 5 seconds or 10 seconds in EDTA group, there was a significant difference between the scores of the crown and middle area of the root canal and the control group (P<0.05), and there was no significant difference in the apical area (P>0.05). There was a significant difference between the 20-40 second group and the first two groups (P<0.05). There was a significant difference between the 50 second group and the other groups (P<0.05). Comparing the cleaning effect on the smear layer after 50 seconds of irrigating between the two experimental groups, the whole root canal showed significant statistical difference (P<0.05). @*Conclusion @#The EDTA-assisted sonic activated device used for 50 seconds has the best cleaning effect.

3.
Braz. dent. sci ; 26(3): 1-13, 2023. ilus, tab
Article in English | LILACS, BBO | ID: biblio-1444656

ABSTRACT

Objective: this double-blind randomized clinical trial evaluate the clinical performance of Thermo-Viscous Bulk Fill composite, Self-Adhesive Flowable composite, and Filtek Bulk Fill Composites restorations in Class I cavities over a period of 18 months. Material and Methods: twenty individuals between the ages of 30 and 45 participated in this research. Each patient should have at least three occlusal Class I carious lesions on their molars. They were dispersed at random, with n=20 teeth representing each tested material. Group I (Futurabond M+ and VisCalor Bulk Fill which heated in a viscolar dispenser at 68 °C for 30s and placed in a 4 mm thickness), Group II (Fusio Liquid Dentin self-adhesive composite which put in a thin layer (1mm increment)), and Group III (Single Bond Universal and Filtek Bulk Fill Posterior composite which applied in 4 mm thickness without heating). Using (USPHS) criteria, all restorations were assessed clinically at baseline, 6 months, 12 months, and 18 months. Using an inverse replica, the marginal seal of the investigated restorations was further evaluated under SEM. Statistical analysis was performed with Chi-square test for all USPH parameters. Results: the three tested groups recorded a one hundred percent retention rate after 18 months follow up period. Concerning marginal adaptation, marginal discoloration, anatomical form, surface texture, and color matching, there was a significant difference (p˂0.05) between the three tested groups after 12 & 18 months. After 12 & 18 months, SEM analysis of the marginal seal revealed a statistically significant difference between the three groups. Conclusion: Bulk fill resin composite restorations showed satisfactory acceptable clinical performance after 18 months of clinical service compared to self-adhesive flowable composites, and Viscalor Bulk Fill composite demonstrated excellent results with considerable changes in marginal integrity as a consequence of thermal viscous technology and increased adaptability of restorations toward cavity walls and margins (AU)


Objetivo: este ensaio clínico randomizado duplo-cego avaliou o desempenho clínico de restaurações de resina Bulk Fill Termo-Viscosa, resina autoadesiva Flowable e Filtek Bulk Fill Composites em cavidades Classe I durante um período de 18 meses. Material e Métodos: 20 indivíduos com idade entre 30 e 45 anos participaram da pesquisa. Cada paciente deveria ter pelo menos três lesões de cárie oclusais de Classe I nos molares. Eles foram divididos aleatoriamente, com n=20 dentes representando cada material testado. Grupo I (Futurabond M+ e VisCalor Bulk Fill aquecido em dispensador viscolar a 68 °C por 30s e colocado em uma espessura de 4 mm), Grupo II (resina composta autoadesiva Fusio Liquid Dentin colocada em uma camada fina (incremento de 1 mm)) e Grupo III (resina composta Single Bond Universal e Filtek Bulk Fill Posterior aplicado em espessura de 4 mm sem aquecimento). Usando os critérios (USPHS), todas as restaurações foram avaliadas clinicamente no início, 6 meses, 12 meses e 18 meses. Usando uma réplica inversa, o selamento marginal das restaurações investigadas foi avaliado em MEV. A análise estatística foi realizada com o teste qui-quadrado para todos os parâmetros USPH. Resultados: os três grupos testados registraram uma taxa de retenção de cem por cento após um período de acompanhamento de 18 meses. Em relação à adaptação marginal, descoloração marginal, forma anatômica, textura da superfície e combinação de cores, houve uma diferença significativa (p˂0,05) entre os três grupos testados após 12 e 18 meses. Após 12 e 18 meses, a análise SEM do selamento marginal revelou uma diferença estatisticamente significativa entre os três grupos. Conclusão: as restaurações de resina composta Bulk Fill apresentaram desempenho clínico aceitável satisfatório após 18 meses de atendimento clínico em comparação com as resinas compostas fluidas autoadesivas, e a resina composta Viscalor Bulk Fill demonstrou excelentes resultados com mudanças consideráveis na integridade marginal, como consequência da tecnologia viscosa térmica e maior adaptabilidade de restaurações nas paredes e margens da cavidade (AU)


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Microscopy, Electron, Scanning , Malocclusion, Angle Class I
4.
Odovtos (En línea) ; 24(3)dic. 2022.
Article in English | LILACS, SaludCR | ID: biblio-1406165

ABSTRACT

Abstract This study investigated the shear bond strength (SBS) of a universal adhesive to enamel/dentin; 1) that had undergone radiotherapy (RT) and 2) that were readily restored and had undergone RT. Enamel and dentin surfaces were obtained from 90 intact human molars. They were randomly divided into six groups according to the presence and timing of irradiation (RT0:no radiotherapy/control, RT1:RT before restoration, RT2:RT after restoration groups) and adhesive application modes (etch&rinse/ER, self-etch/SE)(n=15). A universal adhesive and resin composites were applied. The radiotherapy protocol was conducted with 60 Gy. The SBS test was subjected (1mm/min) and failure type analysis was performed. The resin-enamel/dentin interfaces were examined. Data were statistically analyzed. For enamel and dentin, the presence and timing of irradiation did not significantly influence the SBS values (p>0.05). For enamel, significantly higher SBS values were obtained using etch&rinse mode than self-etch mode (p<0.05). The predominant failure was mixed type. Loss of enamel prisms and obliterated irregular dentinal tubules were found for the radiotherapy-treated specimens. Resin tags were clearer in the irradiated enamel treated with ER than SE. Irradiation with different timings did not influence the bond strength to enamel and dentin, negatively. Irrespective of radiotherapy, the etch&rinse mode caused higher bond strength to enamel than self-etch mode.


Resumen Este estudio investigó la fuerza de unión al cizallamiento (SBS) de un adhesivo universal al esmalte/dentina en piezas que se habían sometido a radioterapia (RT). Se obtuvieron superficies de esmalte y dentina de 90 molares humanos intactos. Se dividieron aleatoriamente en seis grupos según la presencia y el momento de la irradiación (RT0: sin radioterapia/control, RT1: RT antes de la restauración, RT2: RT después de la restauración considerando los modos de aplicación del adhesivo (n=15). Se aplicó un adhesivo universal y resinas compuestas. El protocolo de radioterapia se realizó con 60 Gy. Se sometió a la prueba adhesiva (1mm/min) y se realizó análisis del tipo de falla. Se examinaron las interfases resina-esmalte/dentina. Los datos fueron analizados estadísticamente. Para el esmalte y la dentina, la presencia y el momento de la irradiación no influyeron significativamente en los valores adhesivos (p>0,05). Para el esmalte, se obtuvieron valores adhesivos significativamente más altos utilizando el modo de grabado y enjuague que el modo de autograbado (p<0,05). La falla predominante fue de tipo mixto. Se encontró pérdida de prismas de esmalte y túbulos dentinarios irregulares obliterados en las muestras tratadas con radioterapia. La irradiación con diferentes tiempos no influyó negativamente en la fuerza de unión al esmalte ni a la dentina. Independientemente de la radioterapia, el modo de grabado ácido y enjuague provocó una mayor fuerza de adhesión al esmalte que el modo de autograbado.


Subject(s)
Humans , Radiotherapy/adverse effects , Turkey , Dental Cementum/drug effects , Head and Neck Neoplasms
5.
Article | IMSEAR | ID: sea-219882

ABSTRACT

Background:Background and objective: One of the unfavourable outcomes of endodontic treatment is furcal perforation. Materials such as MTA-Angelus, Biodentine and Zirconomer have been recommended for the repair of furcal perforations.In this study we compared the sealing ability of MTA-Angelus, Biodentine and Zirconia-reinforced GIC in furcal perforations using dye penetration method. Material And Methods:Access cavities were prepared in extracted mandibular molars (n= 40) using round bur in a high speed hand pieceunder water coolant. Perforations were made in the centre of furcation region using 2mm round bur.The teeth were randomly divided into 4 groups based on the material used to seal the perforation: Group I(n= 12) = MTA –Angelus , Group II (n=12)= Biodentine, Group III(n=12) = Zirconomer , Group IV (n= 4) = left unsealed (negative control group).Leakage at the repaired site was then evaluated using methylene blue dye penetration technique under stereomicroscope and data was statistically analyzed.Result:Minimum dye penetration was observed in biodentine followed by MTA, Zirconomer and control group. The results was not statistically significant (p= .08). Conclusion:According to this study, biodentine showed best of the three materials used for furcation repair.

6.
Journal of Central South University(Medical Sciences) ; (12): 226-237, 2022.
Article in English | WPRIM | ID: wpr-929026

ABSTRACT

OBJECTIVES@#Root canal therapy is the most effective and common method for pulpitis and periapical periodontitis. During the root canal preparation, chemical irrigation plays a key role. However, sodium hypochlorite (NaOCl), the widely used irrigation fluid, may impact the bonding strength between dentin and restorative material meanwhile sterilization and dissolving. Therefore, it's important to explore the influence of NaOCl on the adhesion between dentin and restoration materials to ensure clinical efficacy. This study aims to explore the effect of NaOCl on dentine adhesion and evaluate the effect of dentine adhesion induced by sodium erythorbate (ERY), and to provide clinical guidance on dentin bonding after root canal therapy.@*METHODS@#Seventy freshly complete extracted human third molars aged 18-33 years old, without caries and restorations were selected. A diamond saw was used under running water to achieve dentine fragments which were divided into 10 groups with 14 fragments in each group: 2 control [deionized water (DW)±10% ERY] and 8 experimental groups (0.5%, 1%, 2.5%, and 5.25% NaOCl±10% ERY). The dentine specimens in the control group (treated with DW) and the experimental groups (treated with 0.5% NaOCl, 1% NaOCl, 2.5% NaOCl, and 5.25% NaOCl) were immersed for 20 min using corresponding solutions which were renewed every 5 min. The other 5 groups were immersed in 10% ERY for 5 min after an initial washing with DW for 1 min. Then, we selected 4 dentine fragments from all 14 fragments in each group and the numbers and diameters of opening dentinal tubules were observed under scanning electron microscope (SEM). The other 10 dentine fragments from each group were used to make adhesive samples by using self-etch adhesive wand composite resin. All the above adhesive samples were sectioned perpendicular to the bonded interface into 20 slabs with a cross-sectional area of 1 mm×1 mm using a diamond saw under the cooling water, and then the morphology of 10 slabs in each group's bonding interface was observed from aspects of formation of resin tags, depth of tags in dentin, and formation of hybrid layer under SEM. The other 10 slabs of each group's microtensile bond strength and failure modes were also analyzed.@*RESULTS@#Among the 0.5% NaOCl, 1% NaOCl, 2.5% NaOCl, and 5.25% NaOCl groups, the number and diameter of patent dentinal tubules gradually increased with the rise of concentration of NaOCl solution (all P<0.05). Among the DW, 0.5% NaOCl, 1% NaOCl, 2.5% NaOCl, and 5.25% NaOCl groups, the number and diameter of patent dentinal tubules increased after using ERY, but without significant difference (all P>0.05). Among the DW, 0.5% NaOCl, 1% NaOCl, and 2.5% NaOCl groups, the scores of formation of resin tags under SEM gradually increased with the increase of concentration of NaOCl solution, while the score in the 5.25% NaOCl group decreased significantly compared with the score of the 2.5% NaOCl group (P<0.05). There was no significant difference between using 10% ERY groups and without using 10% ERY groups (all P>0.05). The scores of length of the tags under SEM in the 5.25% NaOCl group was significantly higher than the scores of DW, 0.5% NaOCl, and 1% NaOCl groups (all P<0.05), and it was also higher than the score of the 2.5% NaOCl group, but without significant difference (P>0.05). There was no significant difference between using 10% ERY groups and without using 10% ERY groups (P>0.05). The scores of formation of hybrid layer under SEM in the 2.5% NaOCl and 5.25% NaOCl groups significantly decreased compared with the score of the DW group (all P<0.05). There were significant differences between the 2.5% NaOCl±10% ERY groups and between the 5.25% NaOCl±10% ERY groups (all P<0.05). Microtensile bond strength was greater in the 0.5% NaOCl, 1% NaOCl, and 2.5% NaOCl groups, but lower in the 5.25% NaOCl group than that in the DW group (all P<0.05). There were significant differences between the 2.5% NaOCl±10% ERY groups and between the 5.25% NaOCl±10% ERY groups (all P<0.05). The incidence of type "Adhesive" of failure modes in the 5.25% NaOCl group was significantly higher than that in other groups (all P<0.05), while the incidence of type "Adhesive" in the 5.25% NaOCl+10% ERY group was lower than that in the 5.25% NaOCl group (P<0.05).@*CONCLUSIONS@#The bonding strength to dentine increases with the increase of NaOCl concentration when the concentration lower than 2.5%; whereas it is decreased at a higher concentration (such as 5.25%). 10% ERY has a definite recovery effect on attenuated bonding strength to 5.25% NaOCl-treated dentine.


Subject(s)
Adolescent , Adult , Humans , Young Adult , Ascorbic Acid , Dental Bonding , Dentin , Dentin-Bonding Agents/pharmacology , Diamond/pharmacology , Materials Testing , Microscopy, Electron, Scanning , Resin Cements/pharmacology , Sodium Hypochlorite/pharmacology , Tensile Strength , Water/pharmacology
7.
Journal of Forensic Medicine ; (6): 46-52, 2022.
Article in English | WPRIM | ID: wpr-984094

ABSTRACT

OBJECTIVES@#To construct a YOLOv3-based model for diatom identification in scanning electron microscope images, explore the application performance in practical cases and discuss the advantages of this model.@*METHODS@#A total of 25 000 scanning electron microscopy images were collected at 1 500× as an initial image set, and input into the YOLOv3 network to train the identification model after experts' annotation and image processing. Diatom scanning electron microscopy images of lung, liver and kidney tissues taken from 8 drowning cases were identified by this model under the threshold of 0.4, 0.6 and 0.8 respectively, and were also identified by experts manually. The application performance of this model was evaluated through the recognition speed, recall rate and precision rate.@*RESULTS@#The mean average precision of the model in the validation set and test set was 94.8% and 94.3%, respectively, and the average recall rate was 81.2% and 81.5%, respectively. The recognition speed of the model is more than 9 times faster than that of manual recognition. Under the threshold of 0.4, the mean recall rate and precision rate of diatoms in lung tissues were 89.6% and 87.8%, respectively. The overall recall rate in liver and kidney tissues was 100% and the precision rate was less than 5%. As the threshold increased, the recall rate in all tissues decreased and the precision rate increased. The F1 score of the model in lung tissues decreased with the increase of threshold, while the F1 score in liver and kidney tissues with the increase of threshold.@*CONCLUSIONS@#The YOLOv3-based diatom electron microscope images automatic identification model works at a rapid speed and shows high recall rates in all tissues and high precision rates in lung tissues under an appropriate threshold. The identification model greatly reduces the workload of manual recognition, and has a good application prospect.


Subject(s)
Humans , Diatoms , Drowning/diagnosis , Liver/diagnostic imaging , Lung/diagnostic imaging , Microscopy, Electron, Scanning
8.
Journal of Forensic Medicine ; (6): 40-45, 2022.
Article in English | WPRIM | ID: wpr-984093

ABSTRACT

OBJECTIVES@#To explore the application values of diatom artificial intelligence (AI) search system in the diagnosis of drowning.@*METHODS@#The liver and kidney tissues of 12 drowned corpses were taken and were performed with the diatom test, the view images were obtained by scanning electron microscopy (SEM). Diatom detection and forensic expert manual identification were carried out under the thresholds of 0.5, 0.7 and 0.9 of the diatom AI search system, respectively. Diatom recall rate, precision rate and image exclusion rate were used to detect and compare the efficiency of diatom AI search system.@*RESULTS@#There was no statistical difference between the number of diatoms detected in the target marked by the diatom AI search system and the number of diatoms identified manually (P>0.05); the recall rates of the diatom AI search system were statistically different under different thresholds (P<0.05); the precision rates of the diatom AI system were statistically different under different thresholds(P<0.05), and the highest precision rate was 53.15%; the image exclusion rates of the diatom AI search system were statistically different under different thresholds (P<0.05), and the highest image exclusion rate was 99.72%. For the same sample, the time taken by the diatom AI search system to identify diatoms was only 1/7 of that of manual identification.@*CONCLUSIONS@#Diatom AI search system has a good application prospect in drowning cases. Its automatic diatom search ability is equal to that of experienced forensic experts, and it can greatly reduce the workload of manual observation of images.


Subject(s)
Humans , Artificial Intelligence , Diatoms , Drowning/diagnosis , Liver , Lung , Microscopy, Electron, Scanning
9.
Malaysian Journal of Microbiology ; : 612-619, 2022.
Article in English | WPRIM | ID: wpr-988258

ABSTRACT

Aims@#The rise of drug-resistant infectious diseases worldwide has spurred experts' interest in developing safe and effective alternative medicine. Melaleuca cajuputi extracts have been shown to exhibit antimicrobial activity in vitro against various bacterial species. This study evaluated the antimicrobial activity of local M. cajuputi leaf extracts (MCEs) against Candida albicans.@*Methodology and results@#Phytoconstituents of aqueous and ethanolic MCEs were screened conventionally using chemical tests. Broth microdilution assay and scanning electron microscope (SEM) were performed to study the anti-Candida activity of the extracts. Both MCEs contained terpenoids, phenols, flavonoids and tannins. Aqueous and ethanolic MCEs showed good fungicidal activity against the tested organism with minimum inhibitory concentration (MIC) values of 50 mg/mL and 25 mg/mL, respectively and a minimum fungicidal concentration (MFC) to MIC ratio of less or equal to 2. Scanning electron micrographs revealed yeast cell surface morphology alterations when treated with both MCEs at 1× MIC.@*Conclusion, significance and impact of study@#In conclusion, MCEs have anti-Candida properties and thus, M. cajuputi extract could be an excellent potential source of natural antimicrobial agents for disease remedies.


Subject(s)
Anti-Infective Agents , In Vitro Techniques , Trees
10.
Journal of Prevention and Treatment for Stomatological Diseases ; (12): 151-156, 2021.
Article in Chinese | WPRIM | ID: wpr-862451

ABSTRACT

Objective@# To study the effects of different concentrated sulfuric acid etching durations on the shear bond strength between polyether-ketone-ketone (PEKK) and dentin, providing a scientific basis for the clinical bonding procedures of PEKK prosthesis.@*Methods@# Forty-four PEKK specimens were prepared and randomly divided into four groups: group A was the control group, which was only polished with abrasive papers, group B, group C and group D were experimental groups, which were etched by 98% concentrated sulfuric acid for 5 s, 30 s and 60 s, respectively. In addition, one sample was randomly selected from each group, and the profile was prepared by a slow cutting machine. The surface morphology of the profile was observed under SEM. After the four groups of specimens and dentin were bonded by resin, they were soaked in distilled water at 37 ℃ for 24 h. After the shear bonding strengths were measured, the fracture interfaces of the specimens were examined by the scanning electron microscopy and stereomicroscopy, and failure models of bonding were analyzed. @*Results@#After acid etching treatments, the cross-sectional images in group B presented uniform spongy shapes, while the cross-sectional images in group C and group D showed destructive pore structures. The shear bond strengths of group B (16.84 ± 1.84) MPa, group C (12.33 ± 1.22) MPa and group D (6.44 ± 1.18) MPa were higher than that of group A (3.99 ± 1.06) MPa (P < 0.05). The highest shear bond strength was observed in group B (16.84 ± 1.84) MPa. @*Conclusion @#The surface treatment of 98% sulfuric acid etching for 5 s manifested the best bond strength between PEKK and dentin.

11.
Journal of Forensic Medicine ; (6): 158-165, 2021.
Article in English | WPRIM | ID: wpr-985203

ABSTRACT

Objective To observe the skin ultrastructure change of electric shock death rats and to test the expression changes of hypoxia-inducible factor-2α (HIF-2α) and heart type-fatty acid-binding protein (H-FABP) of myocardial cells, in order to provide basis for forensic identification of electric shock death. Methods The electric shock model of rats was established. The 72 rats were randomly divided into control group, electric shock death group and postmortem electric shock group. Each group was divided into three subgroups, immediate (0 min), 30 min and 60 min after death. The skin changes of rats were observed by HE staining, the changes of skin ultrastructure were observed by scanning electron microscopy, and the expression of HIF-2α and H-FABP in rats myocardium was tested by immunohistochemical staining. Results The skin in the electric shock death group and postmortem electric shock group had no significant difference through the naked eye or by HE staining. Under the scanning electron microscope, a large number of cellular debris, cells with unclear boundaries, withered cracks, circular or elliptical holes scattered on the cell surface and irregular edges were observed. A large number of spherical foreign body particles were observed. Compared with the control group, the expression of HIF-2α in all electric shock death subgroups increased, reaching the peak immediately after death. In the postmortem electric shock group, HIF-2α expression only increased immediately after death, but was lower than that of electric shock death group (P<0.05). Compared with the control group, the expression of H-FABP in all subgroups of electric shock death group and postmortem electric shock group significantly decreased. The expression of H-FABP in all subgroups of electric shock death group was lower than that of the postmortem electric shock group (P<0.05). Conclusion Electric shock can increase HIF-2α expression and decrease H-FABP expression in the myocardium, which may be of forensic significance for the determination of electric shock death and identification of antemortem and postmortem electric shock.


Subject(s)
Animals , Rats , Autopsy , Basic Helix-Loop-Helix Transcription Factors/metabolism , Fatty Acid Binding Protein 3/metabolism , Myocardium/metabolism , Myocytes, Cardiac/metabolism , Skin/ultrastructure
12.
Int. j. morphol ; 38(6): 1779-1785, Dec. 2020. tab, graf
Article in English | LILACS | ID: biblio-1134511

ABSTRACT

SUMMARY: The Bactrian camel, which is native to China and Mongolia, is large in size and is an even-toed ungulate species. The double humps on the Bactrian camel back differentiate it from the dromedary camel, which has a single hump. This species has adapted to unsuitable conditions (lack of food and water) in the Gobi Desert and is advanced in unique anatomical and physiological characteristics during a prolonged evolution period. Several studies have been conducted on the anatomical features of the Bactrian camel, but none have given attention to the alveolar capillaries of the Bactrian camel lung. Therefore, the current study aims to explore the architecture of the alveolar capillary in the Bactrian camel lung and further explain the mechanism of blood flow in its lung. The current study extracted and examined the architecture of the alveolar capillary in the lung of the Bactrian camel (Camelus bactrianus) and further explained the mechanism of blood flow by performing lung casting and replica scanning electron microscopy methods. The reports showed that the resources of the alveolar-capillary originated from the capillaries of the subpleural space or interlobular septulum, sometimes originating from the precapillary arterioles or directly from the terminal arterioles. The alveolar capillaries anastomosed and formed a single layer of dense, basket-like network surrounding the alveolus. The mash diameter of the alveolar-capillary network was larger than that of the capillary, and the appearance of the mash was oval and elliptical. Many of the collapsed alveolar-capillary networks were found in the alveolar microvascular architecture in the lung of the Bactrian camel. The study found that, due to many collapsed alveoli in the Bactrian camel lung, the disproportional pressure between the pulmonary alveoli induced less imbalance of blood flow in the alveolar capillary, which affected the gas exchange efficiency. Therefore, the function of the anastomosing capillary branch was likely to regulate the blood flow between the alveolar-capillary network.


RESUMEN: El camello bactriano, es originario de China y Mongolia, es de gran tamaño y es una especie de ungulado de dedos pares. Las dobles jorobas del lomo del camello bactriano lo diferencian del dromedario, que tiene una sola joroba. Esta especie se ha adaptado a condiciones inadecuadas (falta de alimento y agua) en el desierto de Gobi y ha avanzado en características anatómicas y fisiológicas únicas durante un período de evolución prolongado. Se han realizado varios estudios sobre las características anatómicas del camello bactriano, pero ninguno ha prestado atención a los capilares alveolares del pulmón de este animal. Por lo tanto, el presente estudio tuvo como objetivo principal explorar la arquitectura del capilar alveolar en el pulmón del camello bactriano y explicar el mecanismo del flujo sanguíneo. A partir de nuestro trabajo se examinó la arquitectura del capilar alveolar en el pulmón del camello bactriano (Camelus bactrianus) mediante la realización de métodos de microscopía electrónica de barrido y escaneo pulmonar. Los informes mostraron que los recursos del alvéolo-capilar se originaban en los capilares del espacio subpleural o del tabique interlobulillar y a veces se originaban en las arteriolas precapilares o directamente en las arteriolas terminales. Los capilares alveolares se anastomosaban y formaban una densa red de capa única en forma de cesta que rodeaba el alvéolo. El diámetro del macerado de la red alveolar-capilar era mayor que el del capilar y el aspecto del macerado era ovalado y elíptico. Muchas de las redes alvéolo-capilares colapsadas se encontraron en la arquitectura microvascular alveolar en el pulmón del camello bactriano. El estudio encontró que, muchos alvéolos colapsados en el pulmón del camello bactriano, la presión desproporcionada entre los alvéolos pulmonares inducía un menor desequilibrio del flujo sanguíneo en el capilar alveolar, lo que afectaba la eficiencia del intercambio de gases. Por lo tanto, la función de la rama capilar anastomosante probablemente regularía el flujo sanguíneo entre la red alveolar-capilar.


Subject(s)
Animals , Pulmonary Alveoli/blood supply , Pulmonary Alveoli/ultrastructure , Capillaries/anatomy & histology , Capillaries/ultrastructure , Camelus/anatomy & histology , Lung/blood supply , Lung/ultrastructure , Microscopy, Electron, Scanning
13.
Rev. bras. entomol ; 64(4): e20200028, 2020. graf
Article in English | LILACS-Express | LILACS | ID: biblio-1137756

ABSTRACT

Abstract Here we describe three new species of Cordiluroides Albuquerque, one striking new species from Brazil, Minas Gerais, C. albitarsata sp. nov., and two from Peru, Cuzco, C. inca sp. nov. and C. wayqechensis sp. nov. Additionally, photographs from the types of C. listrata Albuquerque, 1954, C. megalopyga Albquerque, 1954 and C. insularis (Williston, 1896) are included. With the new species, Cordiluroides is now known from 11 species exclusively distributed in the Neotropical region with records from Bolivia, Brazil, Colombia, Costa Rica, Mexico, Saint Vincent, and Peru. We give an updated identification key to species from the Neotropical region. Finally, we describe for the first time the external morphology and genitalia of the Cordiluroides species using Scanning Electron Microscope (SEM) images.

14.
Chinese Journal of Tissue Engineering Research ; (53): 1566-1570, 2020.
Article in Chinese | WPRIM | ID: wpr-847731

ABSTRACT

BACKGROUND: The preparation and cleaning of severely curved root canal is the difficult point of root canal treatment. A large number of smear layer will be produced in the process of root canal preparation. Removing effectively these debris and smear layer will be conducive to improving the success rate and longterm effect of severely curved root canal treatment. OBJECTIVE: To explore the cleaning efficacy of Twisted File and ProTaper file combined with chemical preparation on smear layer of severely curved root canal by scanning electron microscope. METHODS: Twenty clinically extracted mandibular molars with severely curved root canals were collected and randomly divided into two groups: Twisted File group and ProTaper group. The root canals were prepared by Twisted file and ProTaper Ni-Ti file, respectively. They were prepared by chemical method with 3% NaClO and 17% EDTA. After preparation, the root canals were split longitudinally and the cleaning efficacy of smear layer of coronal, middle and apical thirds was observed by scanning electron microscope. RESULTS AND CONCLUSION: (1) The images of scanning electron microscope showed that the dentinal tubules of root canal coronal thirds in the ProTaper group and Twisted file group were completely open, almost without smear layer. Dentinal tubules of middle thirds were also open, and simply part of them were covered by smear layer. However, dentinal tubules of apical thirds had few and no obvious opening, and was covered by a large number of smear layer. (2) In Twisted file group, the scores of smear layer at root canal apical thirds were higher than coronal and middle thirds (P 0.05). (3) The results showed that the chemo-mechanical preparation with Twisted File and ProTaper could remove effectively the debris and smear layer in the root canal walls of coronal and middle thirds of the severely curved crown, but the removal effect on apical thirds and dentin tubules was not good.

15.
Chinese Journal of Tissue Engineering Research ; (53): 3157-3161, 2020.
Article in Chinese | WPRIM | ID: wpr-847467

ABSTRACT

BACKGROUND: Articular cartilage has a high-weight-bearing area and a low-weight-bearing area. There are different macroscopic elastic moduli in the two regions, but the modulus of the two areas at the micro and nano levels is unknown. Such information is important for further understanding of cartilage micro and nano mechanics. Moreover, the micro and nano structures of the two areas, which influence the cartilage mechanical properties, should be discussed. OBJECTIVE: To investigate the mechanical properties and structure of high- and low-weight-bearing areas of the hip articular cartilage at the micro and nano levels. METHODS: Normal porcine femoral head cartilage was used. Atomic force microscopy with a spherical tip of 5 µm in diameter was used to measure the microscale compressive elastic modulus of different weight-bearing areas of the cartilage. The nanoscale compressive elastic modulus, nano structure, and collagen fiber diameter were measured using a ScanAsyst-Air probe with a radius of curvature of 5 nm. Scanning electron microscopy was employed to identify the microstructure of different weight-bearing areas of the cartilage. RESULTS AND CONCLUSION: The microscale elastic modulus of the high-weight-bearing area of the femoral head cartilage was (433.05±146.52) kPa, and the microscale elastic modulus of the low-weight-bearing area was (331.19±84.88) kPa. The nanoscale elastic modulus of the high- and low-weight-bearing areas of the femoral head cartilage was (1.24±0.42) GPa and (1.28±0.41) GPa, respectively. While no statistically significant differences were found in the elastic modulus of collagen fibers at the nano level (P=0.846 2). The collagen fibers of the high-weight-bearing area arranged more regularly than those of the low-weight-bearing area at the micro level. No significant differences between collagen fiber diameter of the two areas at the nano level were observed (P=0.926 4). To conclude, the collagen fibers of the high-weight-bearing area are cross-linked more regularly than those of low-weight-bearing area. Therefore, the compressive elastic modulus of the high-weight-bearing area at the micro level is significantly higher than that of the low-weight-bearing area, which is consistent with the macroscopic compressive elastic modulus trend. However, high-weight-bearing has no impact on individual collagen fibers at the nano level.

16.
Journal of Prevention and Treatment for Stomatological Diseases ; (12): 494-498, 2020.
Article in Chinese | WPRIM | ID: wpr-823069

ABSTRACT

Objective@# Comparision of the central location ability and clearance rate of ProTaper retreatment, Fengdu O-file and M3-RT three kinds of nickel-titanium instruments and hand stainless instruments K-file, H-file. Observe the form of the root canal wall. To provide experimental basis and reference for the clinical application of nickel-titanium instruments for root canal retreatment.@*Methods @#40 simulated resin blocks with the same specification were randomly divided into four groups (n=10). Each group was separately prepared with hand stainless instruments K-file and H-file (group A1), ProTaper retreatment (group B1), Fengdu O-file (group C1), and M3-RT (group D1). Using scanner to obtain the pre- and post-operative images and overlapping the images through Photoshop. Measuring the root canal inner and outer wall resin removal with Image J, compared the central location ability of the four group. A total of 60 mandibular single canal premolars extracted due to orthodontics were collected. The teeth were randomly divided into four groups (n=15) after filling the root canal. Use hand stainless instruments K-file,H-file(group A2), ProTaper retreatment (group B2), Fengdu O-file(group C2) , M3-RT(group D2) to remove the filling materials. The roots were longitudinally sectioned, and the image of the root surface was photographed under the 10 × magnification microscope. The software was used to trace the area of the root canal wall and residual root filling, and the root filling clearance rate of each group was calculated. Two teeth were randomly selected in each group and observed under scanning electron microscope.@*Results@#Within 9 mm from the root tip hole, the central location ability of group B1, C1, D1 was better than that of group A1(P < 0.05). At 4 mm from the root tip hole, group D1 has the best central location ability(P < 0.05). There was no difference of the four instruments at a distance of 10 mm from the root tip hole(P > 0.05). There were various degree of filling material remained in the root canal after the four groups of instruments for retreatment canal preparation. There was no significant difference between group B2, C2, D2(P > 0.05), and both were higher than group A2(P < 0.05). Scanning electron microscope observation results shown that the root canal wall prepared by group B2, C2, D2 was more smooth and continuous than group A2, and the residual filling material was less. @*Conclusion @#The central location ability of three kinds of nickel-titanium root canal retreatment instruments were significantly better than that of hand stainless instruments. ProTaper retreatment, Fengdu O-file and M3-RT three kinds of nickel-titanium root canal retreatment instruments showed good performance, the central location ability of M3-RT was slightly better. Nickel-titanium root canal retreatment instruments are more efficient than traditional hand stainless instruments in removing root fillings and the root canal wall after preparation is smoother and has good continuity.

17.
Article | IMSEAR | ID: sea-192282

ABSTRACT

Aims: The objective of this in vitro study was to find out the efficacy of Novamin in remineralizing enamel surface on which artificial caries lesion had been created. The changes were analyzed using Vickers Hardness Testing Machine and Scanning electron microscope (SEM). Settings and Design: A total of 40 primary teeth were selected and divided into two groups: Control group and SHY NM (Novamin). All the samples were subjected to ph cycle protocol and assessed using Vickers Hardness Testing Machine and Scanning electron microscope. Each demineralized sample was randomly divided into two groups: Gp I –Control group, Gp II – Novamin (SHY NM). After 10-day period of ph cycle, the obtained data was analyzed statistically. Statistical Analysis Used: Pre and post groups were compared by paired t test. The significance of mean difference between the groups was done by Tukey's post hoc test after ascertaining normality by Shapiro-Wilk (W) test and homogeneity of variance by Levene's test. A two-tailed P value less than 0.05 (P < 0.05) was considered statistically significant. All analyses were performed on SPSS software (Windows version 17.0). Results: Statistical analysis showed that bioactive glass (novamin) remineralizes artificially induced carious lesion in primary teeth. Conclusions: SHY NM (Novamin) exhibited superior remineralization potential.

18.
Braz. dent. sci ; 22(3): 305-312, 2019. tab, ilus
Article in English | LILACS, BBO | ID: biblio-1008364

ABSTRACT

Objective: The aim of the study was to evaluate the influence of different surface post-etching treatments in flexural strength, contact angle and surface roughness of a lithium disilicate ceramic. Material and Methods: 60 bars (16 x 2 x 4 mm) were divided in six groups (n=10): C, no treatment; HF, hydrofluoric acid for 20 s (HF) + washing (60 s), drying (30s); HFL, HF + washing (60 s), drying (30 s) and luting; HFNL, HF + washing (60 s) + neutralization with sodium bicarbonate (SB) for 40 s + washing (5s), drying (30 s) and luting; HFUL, HF + washing (60 s) + ultrasonic bath (UB) for 4 min, drying (30 s) and luting; HFNUL, HF + washing (60 s) + SB (40 s) + UB (4 min) and luting. The bars were submitted to three-points flexural strength test. 25 ceramic blocks (12 x 7 x 7 mm) were divided into five groups (n=5) to evaluate roughness and contact angle C - no treatment; HF - HF ; HFU - HF and UB for 5 min ; HFN - HF and SB; HFNU - HF, UB and SB. A scanning electron microscope (SEM) showed the surface of the samples. ANOVA one-way statistical analysis was done for comparison of results. Results: There was no statistical difference for flexural strength (p-value = 0.15) and for surface roughness (p-valor = 0.15). However, it was obtained statistically significant difference for contact angle (p-valor = 0.00). SEM images showed precipitates after the acid etching, which were removed by post-etching treatments. Conclusion: It can be concluded that the different post-etching surface treatments did not increase the flexural strength, surface roughness, but it influenced the ceramic wetting and SEM images (AU)


Objetivo: O objetivo do estudo foi avaliar a influência de diferentes tratamentos pós-condicionamento na resistência à flexão, ângulo de contato e rugosidade superficial de uma cerâmica de dissilicato de lítio. Material e Métodos: 60 barras (16 x 2 x 4 mm) foram divididas em seis grupos (n = 10): C, sem tratamento; HF, ácido fluorídrico durante 20 s (HF) + lavagem (60 s), secagem (30 s); HFL, lavagem com HF + (60 s), secagem (30 s) e cimentação; HFNL, HF + lavagem (60 s) + neutralização com bicarbonato de sódio (SB) por 40 s + lavagem (5s), secagem (30 s) e cimentação; HFUL, HF + lavagem (60 s) + banho ultrassônico (UB) por 4 min, secagem (30 s) e cimentação; HFNUL, HF + lavagem (60 s) + SB (40 s) + UB (4 min) e cimentação. As barras foram submetidas ao teste de resistência à flexão de três pontos. 25 blocos cerâmicos (12 x 7 x 7 mm) foram divididos em cinco grupos (n = 5) para avaliação da rugosidade superficial e ângulo de contato C - sem tratamento; HF - HF; HFU - HF e UB por 5 min; HFN - HF e SB; HFNU - HF, UB e SB. Um microscópio eletrônico de varredura (MEV) foi utilizado para análise da superfície das amostras. A análise estatística unidirecional ANOVA-um fator foi realizada para comparação dos resultados. Resultados: Não houve diferença estatística para a resistência à flexão (p-valor = 0,15) e para a rugosidade superficial (p-valor = 0,15). No entanto, obteve-se diferença estatisticamente significante para o ângulo de contato (p-valor = 0,00). Imagens de microscopia eletrônica de varredura mostraram a formação de precipitados após o ataque ácido, que foram removidos pelos tratamentos pós-condicionamento. Conclusão: Pode-se concluir que os diferentes tratamentos de superfície pós-condicionamento não aumentaram a resistência à flexão, rugosidade da superfície, mas influenciaram na molhabilidade da cerâmica e nas imagens em MEV.(AU)


Subject(s)
Electron Microscope Tomography , Flexural Strength , Hydrofluoric Acid
19.
Journal of Korean Academy of Pediatric Dentistry ; (4): 101-110, 2019.
Article in Korean | WPRIM | ID: wpr-787349

ABSTRACT

The aim of this study was to evaluate and compare the microstructural properties and mineralization quality of mesiodens with permanent and primary central incisors.Fifteen mesiodens, permanent and primary central incisors were collected. The enamel rod diameter and enamel thickness were observed and measured using field emission scanning electron microscope (FE-SEM). Chemical composition of the enamel was analyzed using energy dispersive X-ray spectrometer (EDS). The measurements were then assessed using the one-way ANOVA and Tukey test.There was no statistically significant difference in the enamel rod diameter between mesiodens and permanent central incisors. However, enamel rods of primary central incisors were smaller than remaining two groups. The thickness of enamel was thick in order of permanent central incisors, mesiodens, primary central incisors. In the composition analysis using EDS, there was no difference in the Ca/P ratio and Ca/C ratio between mesiodens and permanent central incisors, but small in primary central incisors.In conclusion, the microstructural properties of mesiodens were more similar to those of permanent central incisors compared to primary central incisors. Futher, the mineralization quality of mesiodens did not differ significantly from that of permanent central incisors.


Subject(s)
Dental Enamel , Incisor , Miners
20.
China Journal of Chinese Materia Medica ; (24): 2026-2031, 2019.
Article in Chinese | WPRIM | ID: wpr-773133

ABSTRACT

Heortia vitessoides is the most serious pest of Aquilaria sinensis,which is an economically important evergreen tree native to China and is the principal source of Chinese agarwood. In severe infestations,the insects completely eat up the leaves of A. sinensis,causing severe economic losses. In a more recent study,we found that the antennal sensilla of adult play important roles in the host location,mating and oviposition of H. vitessoides. Here,the external morphology of the antennal sensilla of H. vitessoides were examined using scanning electron microscopy. The result showed that the antennae of both sexes of H. vitessoides were filiform in shape,which consist of the scape,pedicel and about 64 segments of flagellomeres. Eight morphological sensilla types were recorded in both sexes,including sensilla trichodea,sensilla chaetica,sensilla basiconica,sensilla coeloconica,sensilla styloconica,sensilla auricillica,sensilla squamiformia and böhm bristle. Major differences were recorded in the distribution and quantity of different sensilla types in each segment of antenna. The sensillas are almost confined to the ventral and lateral surfaces rather than the back side of antennae. Antennal flagella contained the most sensilla while the scape and pedicel segments only contained böhm bristles and sensilla squamiformias. Sensilla trichodea Ⅲ were only found on male antennae. These results are discussed in relation to the possible roles of the sensilla types in the host location,mating and oviposition selection behavior of H. vitessoides.


Subject(s)
Animals , Female , Male , China , Lepidoptera , Microscopy, Electron, Scanning , Sensilla , Thymelaeaceae
SELECTION OF CITATIONS
SEARCH DETAIL